| General | |
|---|---|
| IFC | Certified IFC 2x3 interface completely implemented |
| Basic and Building Model | |
|---|---|
| Product database | Added new components with predefined U-values |
| Electrical | ||
|---|---|---|
| PV | Polysun Inside, updated to version 7.1.8.19822. | |
| KNX layouts | New | |
| XKFA | Universal dimming actuator 3 fold 1xMCB 3x3 leads | |
| XLFA | Valve drive actuator 6 fold (2x3) 2xMCB 6x3 leads | |
| X2FA | Valve drive actuator 6 fold 1xMCB 6x3 leads | |
| XLFA1 | Valve drive actuator 12 fold START 2xMCB 6x3 leads | |
| X3FA | -> Valve drive actuator 12 fold END 2xMCB 6x3 lds | |
| X4FA1 | Analogue actuator 4 fold 1xMCB 4x4 leads | |
| X4FA | Analogue actuator 4 fold 1xMCB 4x4 leads | |
| Enhanced by single placeable channels | ||
| XEFA | KNX Lightcontrol 2-fold 1-10V /2xMCB/4x Cable | |
| XFFA | KNX Lightcontrol 4-fold 1-10V /4xMCB/8x Cable | |
| XZFA | Control unit 1 fold 1-10 V 1xMCB 1x5 leads | |
| XIFA1 | KNX Switch-/Dimm act. 2-fold, 1-10V/2xMCB/2x5 Leads | |
| XIFA4 | Control unit 3 fold 1-10 V 3xMCB 3x5 leads | |
| XIFA2 | KNX Switch-/Dimm act. 4-fold, 1-10V/4xMCB/4x5 Leads | |
| XIFA3 | KNX Switch-/Dimm act. 8-fold, 1-10V/8xMCB/8x5 Leads | |
| Ventilation | |
|---|---|
| 2D/3D | Automatic correct presentation of AHU when switching model views (without manual Repaint Screen Contents [RP]). |
| Basic and Building Model | |
|---|---|
| Basics | Fixed missing snap points when special layers are switched off. |
| Plotting | Fixed wrong presentation in case of objects with huge distance to origo. |
| Fixed missing items of hidden layers in the dialog Edit layer state. | |
| Corrected font size in several title fields. | |
| Export DWG | Fixed missing texts (in title field) in exported DWG. |
| IFC | Fixed wrong position of single objects in exported IFC model. |
| Electrical | |
|---|---|
| Installation | ESYLUX product database updated. |
| Fixed missing load values of objects in case of connection via cable trunk. | |
| Fixed error when move a single object inside an object group. | |
Fixed wrong alignment of a cable duct (with Horizontal). |
|
| Distribution board configuration | Fixed incorrect deletion of a sheet reference of a removed circuit. |
| Corrected load calculation in level 2. | |
| Export GMC-I | Measuring device at USB get recognized. |
| Lightning protection | Optimized conversion of projects from older DDS-CAD versions. |
| Sanitary & Heating | |
|---|---|
| Pipe network | Transfer symbols (direction arrows) to adjacent storeys always use the same colour as its pipe. |
| Dimension change of a pipe is applied to the selected flanges. | |
| Corrected presentation of medium AEL Exhaust Sewage. | |
| Ventilation | |
|---|---|
| Sound calculation | Plenums corrected. |
| Pressure loss calculation | Tees corrected. |