The dialog configures the properties of an object for waste water pipes . The function covers the following subgroups:
- Gully
- Drainage channel
- Manhole
- Separator
Settings, functions and parameters
Properties

The field indicate the main properties of the selected product. The relevant values are taken from the product database and cannot be changed. You can insert a value in this field, this value is irrelevant for the specific object.

With the setting (0/1) you define the medium to be derived.
Setting | Effect |
---|---|
0 | Wastewater |
1 | Rainwater |
Placement

Selection of a reference line in the building to define the mounting height. The selected product determines the reference to the object.
For this function, there are products for surface mounting (on the ceiling) and flush mounting (in the ceiling).
Setting | Effect | ||
---|---|---|---|
Roof Type Mounting | Flush Type Mounting | ||
Ceiling (FCL) |
![]() |
![]() |
The value at |
Suspended Ceiling (SCL) |
![]() |
![]() |
The value at |
Finished Floor (FFL) |
![]() |
![]() |
The value at |
Slab (SSL) |
![]() |
![]() |
The value at |
Free |
![]() |
![]() |
The mounting height is independent of the building model. The value in |
User 1 - …User 4 - |
![]() |
![]() |
The entries User 1 - to User 4 - contain variable standard heights. You can select and modify a standard height (e.g. User 3 - 0.850). To do so, |

Depending on the selected product for flush or surface mounting: distance between the selected reference and the upper or lower edge of the object.
In the case of settings Free and
User 1 - … User 4 - you can enter the mounting height as a number with the desired length unit.


Change-over switch for the operating direction of the value in Distance.
![]() |
Installation above the selected reference. |
![]() |
Installation below the selected reference. |

Setting for the behaviour of the object in the event that the height of the selected reference in the building model changes. Example
Setting | Effect |
---|---|
![]() |
DDScad calculates a new value for |
![]() |
DDScad checks changes in the height ratio between the object and the selected reference using the function Check and Verify Models. |
Type

DDScad differentiates the parts list based on the number (= product number). It is set when the item is selected, but can be entered manually if known.

Setting | Effect |
---|---|
![]() |
The object is included in the parts list. |
![]() |
The object is not included in the parts list. |

Opens the product database and allows the selection of a product.